1 AWG 19 Strand Copper Primary UD Cable 12 AWG Full Neutral TR XLPE/PVC MV 90 100% 175 mil 15 kV - Heavy Duty Electrical Wiring for Industrial Power Distribution and Underground Utility Installations
1 AWG 19 Strand Copper Primary UD Cable 12 AWG Full Neutral TR XLPE/PVC MV 90 100% 175 mil 15 kV - Heavy Duty Electrical Wiring for Industrial Power Distribution and Underground Utility Installations

1 AWG 19 Strand Copper Primary UD Cable 12 AWG Full Neutral TR XLPE/PVC MV 90 100% 175 mil 15 kV - Heavy Duty Electrical Wiring for Industrial Power Distribution and Underground Utility Installations

$27.5 $50 -45% OFF

Free shipping on all orders over $50

7-15 days international

11 people viewing this product right now!

30-day free returns

Secure checkout

38139807

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

[pdf] [/pdf]

1 AWG 19 Str Copper Primary UD Cable 12 AWG Full Neutral TR-XLPE / PVC MV-90 100% 175 mil 15 kV

Application:

• Underground primary residential and commercial distribution circuits.
• May be used in wet or dry locations, installed in underground ducts or direct burial.

Also Known As:

1 AWG Copper TR-XLPE MV-90 cable, PVC concentric neutral cable 5kV-46kV, 1 AWG  Medium voltage primary UD cable, 5 kV 46 kV MV-90 copper cable, 1 AWG TR-XLPE insulated underground cable.

Standards:

• ICEA S-94-649: Standard for Concentric Neutral Rated Cables 5 – 46 kV.
• AEIC CS8: Specifications for Extruded Dielectric, Shielded Power Cable, Rated 5 – 46 kV.

Maximum operating voltage:
• 5 kV – 46 kV, 100 and 133% IL 
Maximum conductor operation temperatures:
Wet and dry locations 
For TR-XLPE
• Normal: 105 °C
• Emergency: 140 °C
• Short Circuit: 250 °C
For XLPE
• Normal: 90 °C
• Emergency: 130 °C
• Short Circuit: 250 °C

Construction:

• Conductor: Soft annealed uncoated copper Class B compressed or unilay compressed per ASTM B8. On request: strand filled. Sizes: 8 AWG – 1000 kcmil. On request: larger sizes
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE). On request: super clean and super smooth materials.
• Insulation: Thermoset tree-retardant cross-linked polyethylene (TR-XLPE). On request: cross-linked polyethylene (XLPE).
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Concentric Neutral: Soft annealed solid copper wires per ASTM B3, helically applied and uniformly spaced. Full or 1/3 Neutral. On request options: alternate neutral constructions, Water Swellable Powder (WSP), and ripcords.
• Binder Tape: A suitable polyester tape, as required.
• Jacket: Overlying (sleeve) black polyvinyl chloride (PVC)

Features:

• Low tension stripping compounds.
• Sealed conductor passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.
• Strand Filled compound meets compatibility test requirements in accordance with ICEA-T-32-610.
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion of insulation and shields.
• On request, can be UL Listed as MV105 for use in accordance with Article 328 of the NEC.
• On request, two abration resistant ripcords placed longitudinally 180° appart for easy jacket removal.

Specifications:

• Size: 1 AWG 
• Number of Strands: 19
• Nominal OD Over Insulation (In): 0.71
• Number of Wires: 13

• Full Neutral Size: 12 AWG
• Jacket Thickness (mil): 80
• Approximate Outside Diameter (In): 1.12
• Approximate Net Weight lb/kft:  883