1 AWG 3C Aluminum MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV

Application:

• Per NEC, use is limited to 2400 volts maximum
• For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.

Also Known As:

1 AWG Aluminum MV-90 Cable, 1 AWG 3C 2.4kV Non-Shielded Cable, 1 AWG EPR Insulated PVC Cable, 1 AWG Medium Voltage 3C Aluminum, 1 AWG 2.4 kV EPR Cable, 1 AWG Non-Shielded PVC Jacketed Cable, 1 AWG 3 Conductor MV-90 Cable, 1 AWG  Aluminum EPR Cable 2.4 kV, 1 AWG MV-90 3C PVC Cable, 1 AWG 2.4 kV Aluminum Non-Shielded Cable

Standards:

• UL 1072
• Medium Voltage Power Cables.
• ICEA S-96-659/NEMA WC71
• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.

Features:

• UL Listed as MV-90.
• Rated For CT use 1/0 AWG and up.
• Jacket is listed Sunlight Resistant and Oil Resistant I.
• Jacket is flame retardant.

Construction:

 Conductor: hard drawn Aluminum-1350 compacted Class B per ASTM B400.(6 AWG Aluminum) up to 1000 kcmil.
 Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
 Insulation: Thermoset ethylene propylene rubber (EPR).
 Grounding (Optional): One or three soft annealed bare copper conductors cabled with phase conductors.
 Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
 Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.

Specifications:

• Size: 1 AWG 
• Number of Strands: 19
• Conductor Diameter (In): 0.30
• Insulation Thickness (mil): 90
• Ground Conductor Aluminum AWG : 4
• Jacket Thickness (mil): 80
• Approximate Outside Diameter (In): 1.31
• Approximate Net Weight Copper lb/kft: 883
• Ampacity 90 °C: 155