Spend $50, Ship Free Anywhere
1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Cable - 100% Insulation, 175 mil, 15 kV - Ideal for Underground Power Distribution & Industrial Electrical Wiring
1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Cable - 100% Insulation, 175 mil, 15 kV - Ideal for Underground Power Distribution & Industrial Electrical Wiring

1 AWG 3C Aluminum MV-90 Tape Shielded XLPE Cable - 100% Insulation, 175 mil, 15 kV - Ideal for Underground Power Distribution & Industrial Electrical Wiring

$27.5 $50 -45% OFF

Free shipping on all orders over $50

7-15 days international

7 people viewing this product right now!

30-day free returns

Secure checkout

18595560

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

[pdf] [/pdf]

1 AWG 3C Aluminum MV-90 Tape Shielded XLPE 100% Insulation 175 mil 15 kV

Application:

 Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
 May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Also Known As:

1 AWG 3C MV-90 Cable, 3 Conductor Aluminum, Tape Shielded Cable, 1 AWG 3C XLPE Insulation, PVC Jacket, 5kV-35kV Cable, High Voltage Cable, 1 AWG 3C Aluminum MV-90, Electrical Power Cable, Multi-Conductor Cable.

Standards:

 UL 1072
 Medium Voltage Power Cables.
 ICEA S-93-639/NEMA WC74
 5 kV – 46 kV Shielded Power Cables.
 ICEA S-97-682
 Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.
 AEIC CS8
 Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.

Features:

 UL Listed as MV-90.
 Rated as Sunlight Resistance for CT use, 1/0 AWG and larger.
 Oil Resistance I jacket.
 True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Construction:

 Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawnAluminum-1350 compacted Class B per ASTM B400.
 Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
 Insulation: Thermoset crosslinked polyethylene (XLPE).
 Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
 Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap
 Grounding (Optional): One or three soft annealed bare copper or covered conductors cabled with phase conductors.
 Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape.
 Jacket:  Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.

Specifications:

• Size: 1 AWG
• Number of Strands: 19 
• Conductor Diameter (In): 0.30
• Ground Conductor Aluminum AWG: 4 
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In): 1.95
• Approximate Net Weight Aluminum lb/kft: 1689