Description

[pdf] [/pdf]

1 AWG 3C Copper MV-90 Non-Shielded XLPE Insulated PVC Jacketed 2.4 kV

Application:

Per NEC, use is limited to 2400 volts maximum. For use in power system in industrial establishments and utility applications, for dry locations, in accordance with NEC.Maximum operating voltage: • 2.4 kV in accordance with UL • 5 kV 100% • 3 kV 133% per ICEA Maximum conductor operation temperatures: Wet and dry locations • Normal: 90 °C • Emergency: 130 °C • Short Circuit: 250 °C

Also Known As:

1 AWG Copper 3C MV-90, 1 AWG Non-Shielded 2.4 kV, 1 XLPE Insulated cable, 1 AWG PVC Jacketed wire, 1 AWG Medium voltage cable, 1 AWG Electrical power cable, 1 AWG 2.4 kV MV-90 specifications, 1 AWG Industrial copper cable, 1 AWG 3 conductor cable.

Standards:

• UL 1072
• Medium Voltage Power Cables.
• ICEA S-96-659/NEMA WC71
• Standard for Nonshielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.

Features:

• UL Listed as MV-90.
• Rated For CT use 1/0 AWG and up.
• Jacket is Listed Sunlight Resistant and Oil Resistant I.
• Jacket is flame retardant.

Construction:

• Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 Sizes: 8 AWG up to 1000 kcmil.
• Conductor Shield: 
Semi conducting cross-linked polyethylene (XLPE).
• Insulation: 
Thermoset crosslinked polyethylene (XLPE).
• Grounding (Optional): 
One or three soft annealed bare copper conductors cabled with phase conductors.
• Assembly: 
Conductors cabled with non-hygroscopic fillers, as required and binder tape.
• Jacket: 
Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound. 

Specifications:

• Size: 1 AWG 
• Number of Strands: 19
• Conductor Diameter (In): 0.30
• Insulation Thickness (mil): 90
• Ground Conductor Copper AWG : 4
• Jacket Thickness (mil): 80
• Approximate Outside Diameter (In): 1.31
• Approximate Net Weight Copper lb/kft: 1395