1 AWG 3C Copper MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV Power Cable - Underground Electrical Wiring for Industrial & Commercial Use
1 AWG 3C Copper MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV Power Cable - Underground Electrical Wiring for Industrial & Commercial Use

1 AWG 3C Copper MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV Power Cable - Underground Electrical Wiring for Industrial & Commercial Use

$27.5 $50 -45% OFF

Free shipping on all orders over $50

7-15 days international

18 people viewing this product right now!

30-day free returns

Secure checkout

35530599

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

[pdf] [/pdf]

1 AWG 3C Copper MV-90 Tape Shielded XLPE Insulated PVC Jacket 5 kV

Application:

• Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
• May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried where permitted by NEC.

Also Known As:

1 AWG MV-90 Cable, 1 AWG 3 Conductor Copper, 1 AWG Tape Shielded Cable, 1 AWG XLPE Insulation, 1 AWG PVC Jacket, 5kV-35kV Cable, 1 AWG High Voltage Cable, 1 AWG Copper MV-90, 1 AWG Electrical Power Cable, 1 AWG Multi-Conductor Cable.

Standards:

• UL 1072
• Medium Voltage Power Cables.
• ICEA S-93-639/NEMA WC74
• 5 kV – 46 kV Shielded Power Cables.
• ICEA S-97-682
• Standard for Utility Shielded Power Cables Rated 5 kV– 46 kV.
• AEIC CS8
• Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.

Features:

• UL Listed as MV-90.
• Rated as Sunlight Resistance for CT use, 1/0 AWG and larger.
• Oil Resistance I jacket.
• True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.

Construction:

• Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 Sizes: 8 AWG up to 1000 kcmil.
• Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
• Insulation: Thermoset crosslinked polyethylene (XLPE).
• Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
• Metallic Shield: Soft annealed uncoated copper tape, 5 mil thick, 25% minimum overlap.
• Grounding (Optional): One or three soft annealed bare copper or covered conductors cabled with phase conductors.
• Assembly: Conductors cabled with non hygroscopic fillers, as required and binder tape.
• Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.

Specifications:

• Size: 1 AWG
• Number of Strands: 19
• Conductor Diameter (In): 0.30

• Ground Conductor Copper AWG : 4
• Jacket Thickness (mil): 80
• Approximate Outside Diameter (In): 1.51 
• Approximate Net Weight Copper lb/kft: 1704