Spend $50, Ship Free Anywhere
1 AWG 3C Copper MV 105 Tape Shielded EPR 133% Insulation 220 mil CPE Jacket 15 kV Power Cable - Ideal for Industrial, Commercial, and Underground Electrical Installations
1 AWG 3C Copper MV 105 Tape Shielded EPR 133% Insulation 220 mil CPE Jacket 15 kV Power Cable - Ideal for Industrial, Commercial, and Underground Electrical Installations

1 AWG 3C Copper MV 105 Tape Shielded EPR 133% Insulation 220 mil CPE Jacket 15 kV Power Cable - Ideal for Industrial, Commercial, and Underground Electrical Installations

$27.5 $50 -45% OFF

Free shipping on all orders over $50

7-15 days international

15 people viewing this product right now!

30-day free returns

Secure checkout

46941015

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

[pdf] [/pdf]

1 AWG 3C Copper MV-105 Tape Shielded EPR 133% Insulation 220 mil CPE Jacket 15 kV

Application:

 Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities.
 May be used in wet or dry locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.

Also Known As:

1 AWG 3C MV-105 Cable, 3 Conductor Copper, Tape Shielded Cable, EPR Insulation, 1 AWG 3C CPE Jacket, 5kV-25kV Cable, 1 AWG 3C Copper MV-105, Electrical Power Cable, Multi-Conductor Cable.

Standards:

 UL 1072
 Medium Voltage Power Cables.
 ICEA S-93-639/NEMA WC74
 5 kV – 46 kV Shielded Power Cables.
 ICEA S-97-682
 Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
 AEIC CS8
 Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV– 46 kV.

Features:

 UL Listed as MV-105.
 True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
 Rated as Sunlight Resistance for CT use for all cable sizes.

Construction:

 Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
 Conductor Shield: : Semi conducting cross-linked polyethylene (XLPE).
 Insulation: Thermoset ethylene propylene rubber (EPR)
 Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
 Phase ID: Colored strings (black, red and White yarns.)
 Metallic Shield: Soft annealed uncoated copper tape for copper ground conductors or Soft annealed tinned copper tape for aluminum ground conductors, 5 mil thick, 25% minimum overlap.
 Grounding (Optional): One or three soft annealed bare copper or aluminum conductors cabled with phase conductors. 
 Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
 Jacket: Black sunlight resistance and flame retardant thermosetting chlorinated polyethylene (CPE) compound. 

Specifications:

• Size: 1 AWG
• Number of Strands: 19
• Conductor Diameter (In): 0.30
• Ground Conductor Copper AWG: 4
• Jacket Thickness (mil): 110
• Approximate Outside Diameter (In): 2.21
• Approximate Net Weight Copper lb/kft: 2786