[pdf] [/pdf][short] 1 Aluminum Conductor 15KV MV-105 CableAllowable Ampacity for 1 ALUMINUM CONDUCTOR 15KV MV-105 CABLE at 105°C (in duct): 145 AmpsAllowable Ampacity for 1 ALUMINUM CONDUCTOR 15KV MV-105 CABLE at 105°C (in air): 195 AmpsApplications:15kV cable is an electrical wire and a medium voltage cable, installed through direct burial, conduit system, aerial, cable tray, and underground ducts in accordance with National Electric Code. This aluminum direct burial cable with copper shielding performs for normal operations at 105°C, emergencies at 140°C, and short circuiting conditions at 250°C. The 15kV cable does not require pulling lubricants. This electrical cable is used in both wet and dry locations for 15,000 volts power circuits. Also Known As:1 15kv cable, 1 medium voltage cable, 1 medium voltage wire, 1 awg 15kv cable, 1 awg medium voltage cable, 1 awg medium voltage wire, 1 copper tape shield, 1 copper shielding, 1 bury cable, 1 direct burial cable, 1 direct burial power cable, 1 medium voltage power cables, 1 aluminum direct burial cable. Standards:IEEE 383 flame test (1/0 and larger)IEEE 1202 flame test (250MCM and larger) UL 1072 type MV-105, sunlight resistance CT use (1/0 and larger)AEIC CSBConstructionConductors:15kV cable aluminum conductor is made of 1350 aluminum series, which is Class B and stranded in accordance with ASTM B3. The conductor is soft and left bare, which adds to the flexibility of the cable, making it easier to handle and install. The medium voltage power cables with aluminum conductors are also lightweight and hence, cost effective over the heavy copper cables, which are labor intensive.Insulation:Ethylene Propylene Rubber (EPR) is a flexible thermoplastic layer, which covers the aluminum conductors for safety and protection from heat and moisture. EPR has a high dielectric strength and is semi-conducting, ensuring the safety of the user.Metal shield:The non-magnetic copper tape of size 5mil is helically applied around the assembly, with 25% minimum overlap. The copper shielding holds the conductors in position as well as protects them from mechanical stress.Jacket:The 15kV cable jacket consists of tough polyvinyl chloride (PVC), which is black color coded for simpler identification. PVC offers protection from moisture, flames, corrosive chemicals, and abrasion.Specifications:Size (AWG): 1Insulation Thickness (inches): 0.299Nominal Diameter (inches): 0.220Insulation Shield Diameter (inches): 0.78Overall Diameter: 1.00Approx. Weight (lbs./1000ft.): 521Ampacity at 105°C: in duct: 145 AmpsAmpacity at 105°C: in air: 195 AmpsCompatible with ManufacturerHouston Wire & Cable :1-0115KVEPUCAL[/short]Application:To be used in power circuits rated up to 15,000 volts. For installation in open air, duct, conduit, cable tray (1/0 and larger) or direct buried and for use in wet or dry locations. UL approved at 105°C for continuous operation, 140°C for emergency overload and 250°C during short circuit conditions. Conductors:Soft bare 1350 series aluminum, Class B stranding per ASTM Insulation:Heat and moisture resistant natural high dielectric strength EPR-based insulation per ICEA S-97-682 with a semi-conducting thermosetting insulation shield Metal Shield:Helically applied non-magnetic 5mil copper tape with a minimum of 25% overlap Standards:IEEE 383 flame test (1/0 and larger) IEEE 1202 flame test (250MCM and larger) UL 1072 type MV-105, sunlight resistance CT use (1/0 and larger) AEIC CS8
[short]
Allowable Ampacity for 1 ALUMINUM CONDUCTOR 15KV MV-105 CABLE at 105°C (in duct): 145 Amps
Allowable Ampacity for 1 ALUMINUM CONDUCTOR 15KV MV-105 CABLE at 105°C (in air): 195 Amps
15kV cable is an electrical wire and a medium voltage cable, installed through direct burial, conduit system, aerial, cable tray, and underground ducts in accordance with National Electric Code. This aluminum direct burial cable with copper shielding performs for normal operations at 105°C, emergencies at 140°C, and short circuiting conditions at 250°C. The 15kV cable does not require pulling lubricants. This electrical cable is used in both wet and dry locations for 15,000 volts power circuits.
1 15kv cable, 1 medium voltage cable, 1 medium voltage wire, 1 awg 15kv cable, 1 awg medium voltage cable, 1 awg medium voltage wire, 1 copper tape shield, 1 copper shielding, 1 bury cable, 1 direct burial cable, 1 direct burial power cable, 1 medium voltage power cables, 1 aluminum direct burial cable.
IEEE 383 flame test (1/0 and larger)
IEEE 1202 flame test (250MCM and larger)
UL 1072 type MV-105, sunlight resistance
CT use (1/0 and larger)
AEIC CSB
15kV cable aluminum conductor is made of 1350 aluminum series, which is Class B and stranded in accordance with ASTM B3. The conductor is soft and left bare, which adds to the flexibility of the cable, making it easier to handle and install. The medium voltage power cables with aluminum conductors are also lightweight and hence, cost effective over the heavy copper cables, which are labor intensive.
Ethylene Propylene Rubber (EPR) is a flexible thermoplastic layer, which covers the aluminum conductors for safety and protection from heat and moisture. EPR has a high dielectric strength and is semi-conducting, ensuring the safety of the user.
The non-magnetic copper tape of size 5mil is helically applied around the assembly, with 25% minimum overlap. The copper shielding holds the conductors in position as well as protects them from mechanical stress.
The 15kV cable jacket consists of tough polyvinyl chloride (PVC), which is black color coded for simpler identification. PVC offers protection from moisture, flames, corrosive chemicals, and abrasion.
Compatible with Manufacturer
Application:
To be used in power circuits rated up to 15,000 volts. For installation in open air, duct, conduit, cable tray (1/0 and larger) or direct buried and for use in wet or dry locations. UL approved at 105°C for continuous operation, 140°C for emergency overload and 250°C during short circuit conditions. Conductors:
Soft bare 1350 series aluminum, Class B stranding per ASTM
Insulation:
Heat and moisture resistant natural high dielectric strength EPR-based insulation per ICEA S-97-682 with a semi-conducting thermosetting insulation shield Metal Shield:
Helically applied non-magnetic 5mil copper tape with a minimum of 25% overlap
Standards: