Spend $50, Ship Free Anywhere
1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV Cable - Heavy Duty Power Transmission for Industrial Equipment, Mining Machinery, and Commercial Electrical Systems
1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV Cable - Heavy Duty Power Transmission for Industrial Equipment, Mining Machinery, and Commercial Electrical Systems

1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV Cable - Heavy Duty Power Transmission for Industrial Equipment, Mining Machinery, and Commercial Electrical Systems

$27.5 $50 -45% OFF

Free shipping on all orders over $50

7-15 days international

14 people viewing this product right now!

30-day free returns

Secure checkout

61789542

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

[pdf] [/pdf]

1 AWG 3C Copper MV-90 Non-Shielded EPR Insulated PVC Jacketed 2.4 kV

Application:

 Per NEC, use is limited to 2400 volts maximum.
 For use in power system in industrial establishments and utility applications, for dry
locations, in accordance with NEC.

Also Known As:

1 AWG 3C Copper MV-90 Cable, 1 AWG 3C  2.4kV Non-Shielded Cable, EPR Insulated PVC Cable, Medium Voltage 3C Copper, 2.4 kV EPR Cable, Non-Shielded PVC Jacketed Cable, 1 AWG 3C MV-90 Cable, Copper EPR Cable 2.4 kV, MV-90 3C PVC Cable, 1 AWG 3C 2.4 kV Copper Non-Shielded Cable.

Standards:

 UL 1072
 Medium Voltage Power Cables.
 ICEA S-96-659/NEMA WC71
 Standard for Non shielded Cables Rated 2001-5000 Volts for Use in the Distribution of Electrical Energy.

Features:

 UL Listed as MV-90.
 Rated For CT use 1/0 AWG and up.
 Jacket is listed Sunlight Resistant and Oil Resistant I.
 Jacket is flame retardant. 

Construction:

 Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400.
Sizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.
 Conductor Shield:  Semi conducting cross-linked polyethylene (XLPE). 
 Insulation: Thermoset ethylene propylene rubber (EPR).
 Grounding (Optional): One or three soft annealed bare copper conductors cabled with phase conductors.
 Assembly: Conductors cabled with non-hygroscopic fillers, as required and binder tape.
 Jacket: Black sunlight resistance and flame retardant thermoplastic polyvinyl chloride (PVC) compound.

Specifications:

• Size: 1 AWG
• Number of Strands: 19
• Conductor Diameter (In): 0.30
• Insulation Thickness (mil): 90
• Ground Conductor* per Interstice Copper AWG: 4
• Jacket Thickness (mil): 80
• Approximate Outside Diameter: 1.31
• Approximate Net Weight Copper lb/kft: 1438